Skip to content

Native PoE Budget Calculator

Network planning tool

PoE Budget Calculator

Size switch power budgets for access points, cameras, phones and other powered devices before deployment.

LOCAL CALCULATION

Power plan

Enter the switch limits, then add each powered-device group that will share the budget.

Powered devices
Use the maximum switch-side/PSE draw from the device or switch documentation when available.

IEEE PoE reference

802.3af · Type 115.4 W PSE
12.95 W PD
2 pairs
802.3at · Type 230 W PSE
25.5 W PD
2 pairs
802.3bt · Type 360 W PSE
51 W PD
4 pairs
802.3bt · Type 490 W PSE
71.3 W PD
4 pairs

Actual power available at the powered device can be lower because of cabling losses. This is a planning calculator; confirm final power requirements against the switch and powered-device datasheets.

Free tools · Bikram Bhujel

About this PoE budget calculator

A PoE budget calculator by Bikram Bhujel for planning switch deployments. Add the access points, IP cameras, phones and other powered devices you plan to connect, and it totals their draw against the switch's PoE budget and port count, so you find a shortfall before the equipment is on site.

How to use it

  1. Enter the switch's total PoE budget in watts and its number of PoE ports.
  2. Add each device type with its power draw and quantity.
  3. Set a design reserve so some of the budget is kept free, then check the remaining power and ports.

PoE standards at a glance

  • 802.3af (PoE): up to 15.4 W at the switch port, 12.95 W at the device.
  • 802.3at (PoE+): up to 30 W at the port, 25.5 W at the device.
  • 802.3bt Type 3 (PoE++): up to 60 W at the port, 51 W at the device.
  • 802.3bt Type 4: up to 90 W at the port, about 71 W at the device.

Common questions

What is a PoE budget?

It is the total power a switch can supply to all its PoE ports at once. A 24 port switch with a 370 W budget cannot run 24 devices that each need 30 W.

How much headroom should I leave?

Plan to use no more than about 80 percent of the budget. Devices draw more at start-up and under load, and you will probably add devices later.

Should I use the maximum or typical draw of a device?

Use the maximum from the datasheet. Many switches reserve power by PoE class, so the class maximum is what counts against the budget.

Does cable length reduce PoE power?

Yes. Power is lost as heat in the cable, which is why the power at the device is lower than at the port. Stay within 100 metres and use solid copper Cat5e or better.

Made by Bikram Bhujel, infrastructure and systems engineer in Nepal. More free tools: IPv4 subnet calculator, chmod calculator, QR code generator, all tools.